6.0 Menu OUTPUTS
6.1 Working range
Principle
This function defines the two limits for the actual regulation voltage output AO1 (or AO1 and
AO2 when using the No-Stop mode) inside the global output range (-10 / + 10 V). Useful
function when using the controller with a device which only uses 0 - +10V input.
How does it work
Min. threshold: Means the minimum voltage allowed to the controller regulated output
(enter the threshold value between -10V et +10V).
Max. threshold: Means the maximum voltage allowed to the controller regulated output
(enter the threshold value between -10V et +10V - must be higher than the Min. threshold
already defined).
www.cmccontrols.com
30